AMPRO 2000 Gas Analyzer

 

Powerful, Handheld Combustion / Emission Analyser for industrial combustion and emission measurements.

  • Low cost of ownership
  • Extremely user friendly
  • +4 years O2 sensor Life Experience
  • Active CO sensor protection

Simultaneous measurements of up to 7 gas components!

  • 02, CO, C02, NO, NO2, SO2, CO-high, & CO-very high,
    • Up to 5 electrochemical sensors, plus C02/Hydrocarbon NDIR bench is possible!
    • Low CO, NO and NO2 ranges are available
  • Emission calculations such as mass flow, calculated or True NO(x), plus O2 referencing to user defined values
  • Gas temperature measurement up to 2,012F (use stainless steel up to 1,200F, use Incomel tubes up to 2,012F)
  • Large condensate separator with PTFE (Teflon) coated filter
  • Air purging pump for CO-sensor protection
  • Internal data storage for up to 16,000 measurements!
  • High energy Li-ion battery provides up to 15 hours operation
  • Large color graphic, backlit display with zoom function
  • Customizable screen settings
  • Durable and dirt resistant keypad
  • IR interface for external printer (printer is opional)
  • Integrated so card reader for additional memory and easy data handling

Also measures...

  • Combustion air temperature
  • Stack gas temperature
  • Stack draft
  • Differential pressure
  • Differential temperature

And calculates...

  • CO2
  • CO/CO2 ratio
  • Dew point
  • Excess air and air ratio (Lambda)
  • Combustion efficacy
  • Heat losses

Specifications: 

    Measured components Measuring Ranges Resolution T90 Accuracy
    O2 Oxygen 0 … 21.0 Vol-%

     

    OPTIONAL (25%)

    0.1 % < 20 sec. ± 0.2 Vol-% abs.
    CO Carbon monoxide 0 … 4,000 ppm

     

    overload 20,000ppm *1

    1 ppm < 40 sec. ± 10 ppm or 5 % reading < 4,000 ppm / 10 % reading > 4,000 ppm
    CO low Carbon monoxide 0 … 500 ppm

     

    *2

    0.1 ppm < 40 sec. ± 2.0 ppm or 5 % reading
    CO high Carbon monoxide 0 … 4 %

     

    overload 10 % *1

    1 ppm < 40 sec. ± 0.02% or 5 % reading < 0.4% / 10 % reading > 0.4%
    NO Nitric oxide 0 … 1,000 ppm

     

    overload 5,000ppm *1

    1 ppm < 30 sec. ± 5.0 ppm or 5 % reading < 1,000 ppm / 10 % reading > 1,000 ppm
    NO low Nitric oxide 0 … 300 ppm

     

    *2

    0.1 ppm < 30 sec. ± 2.0 ppm or 5 % reading
    NO2 Nitrogen dioxide 0 … 200 ppm

     

    overload 1,000ppm *1

    1 ppm < 40 sec. ± 5 ppm or 5 % reading < 200 ppm / 10 % reading > 200 ppm
    NO2 low Nitrogen dioxide 0 … 100 ppm

     

    *2

    0.1 ppm < 40 sec. ± 2.0 ppm or 5 % reading
    SO2 Sulfur dioxide 0 … 2,000 ppm

     

    overload 5,000ppm *1

    1 ppm < 40 sec. ± 10 ppm or 5 % reading < 2,000 ppm / 10 % reading > 2,000 ppm
    CO2  *3 Carbon dioxide 0 … 40% 0.01 % < 35 sec. ± 0.3 %  or 3% reading
    CO2  *4

     

    CxHy

    Carbon dioxide

     

    Hydrocarbons

    0 … 40%

     

    100 … 40,000 ppm

    0.01 %

     

    10 ppm

    < 35 sec.

     

    < 35 sec.

    ± 0.3 %  or 3% reading

     

    ± 400 ppm or 5% reading

    *1 – overload ranges are recommended only for short time measurements

     

    *2 – are not separate sensors; selected sensors are used with special calibration

    *3 – Single NDIR

    *4 – DUAL NDIR

    Other measured components Measuring Ranges Accuracy
    Stack / Flue gas temperature 32 … 1,472°F (0 … 800°C) with stainless steel

     

    32 … 2,012°F (0 … 1100°C) with Inconel

    ± 4°F … < 392°F / 1 % reading > 392°F

     

    ± 4°F … < 392°F / 1 % reading > 392°F

    Primary air / Ambient air temperature 32 … 212°F    (0 … 100 °C) ± 2°F
    Differential temperature Up to 2,012°F (0 … 1100°C)

     

    (with suitable material of sampling tube)

    ± 4°F … < 392°F / 1 % reading > 392°F
    Stack draft +/- 40 inH2O (100hPa) ± 0.01 inH2O or 1% reading
    Differential pressure +/- 120 inH2O (300hPa) ± 0.01 inH2O or 1% reading
    Gas flow velocity measurement 1 … 40 m/s (using Pitot tube)
    Calculated values Range Calculated values Range
    Carbon dioxide 0 … CO2 max. Air Ratio (Lambda) 1 … 9.99
    Heat losses qA 0 … 99.9 % Excess Air 0 … 99.9
    Efficiency 0 … 100 % / 120 % CO/CO2 ratio 0 … 10
    GENERAL SPECIFICATIONS
    Max suction range gas pump 60 inH2O (150 hPa)
    Typical gas flow 16 gal/h (60 l/h)
    Internal memory 16,000 data sets
    Data transmission via USB, SD Card or Bluetooth
    Interfaces SD card reader, USB, IR, Bluetooth
    Display 3.5″ TFT color display
    Operation temperature 41°F …. 113°F (5 … 45°C) max. 95 % RH, none condensing
    Storage temperature -4°F ….. 122°F (-20°C … 50°C)
    Ambient conditions not in aggressive, corrosive or high dust ambience, not for use in hazardous areas
    Battery operated Lithium-Ion battery, 20 h operation time
    Grid power supply 100 – 240 V AC / 50 … 60 Hz 1.2A
    Protection class IP 30
    Weight approx. 2.2 lbs. (with 7 sensors)
    Dimensions ( W x H x D) 4.3” x 8.8” x 2.04”
    TÜV approval ByRgG 280 acc. 1. BImSchV and EN 50379